High Power HIFU Piezoceramic element OD19.5x4MHz

0 votes
asked Jul 19, 2022 in 3D Segmentation by netcec001 (677,960 points)
Piezoelectric ceramic hemisphere  

 

 

Electrode direction: thickness direction

 

 

 

 

 

Applications:  High Intensity Focused Ultrasound, high power ultrasonic transducer

 

 

 

 

 

 

 

 

Focused ultrasound system has good tissue penetration and localization. It can focus energy through surface tissue and target tissue at a specific depth to produce biological effects, which can make the pathological tissue recover quickly. The dosage of focused ultrasound therapy is easy to control and safe. After treatment, only local tissue has transient congestion and edema, and surface cells can remain intact, quick recovery.

 

Ultrasound focusing has good tissue penetration and energy storage. The host generates high-frequency electrical signals, which are converted into focused ultrasound by transducer. The ultrasound is transmitted to the lesion tissues by circulating water system, sound transmission membrane and contact coupling agent. Ultrasound can produce thermal effect, mechanical effect, cavitation effect and biochemical effect in biological tissues. Polaris uses these characteristics to act on pathological tissues to degenerate them, promote tissue reconstruction and improve microcirculation to achieve therapeutic purposes.

 

 

 

 

 

 

 

 

 

 

Material:  PZT-82( hard PZT P-8)

 

 

 

 

 

Technical data:

 

 

Dimensions:  diameter 19.5mm, thickness according to frequency 4MHz, R 19

 

 

Thickness Frequency Ft: 4MHz ± 100KHz

 

 

Radial Frequency Fr: 112KHz ± 5%

 

 

Electromechanical coupling coefficient Kp: ≥ 0.57 

 

 

 

Resonant impedance Zm: ≤ 3 Ω

 

 

Dielectric Loss tg δ: 0.3%

 

 

Static capacitance Cs: 7200pF± 20%

 

 

 

 

 

 

 

 Test Condition: 25±3 °C 40~70% R.H.

fr, Zm, Kr => Radial mode vibration

Cs tanδ => LCR meter at 1KHz 1Vrms

 

 

 

 

 

 

 

 

 

 

PZT-82 is equal to PZT-8, hard PZT for higher mechanical

quality factor, lower dielectric loss required and much higher power handling

capability etc. transducers.

 

 

 

 

 

 

 

YUHAI piezo material for HIFU systerm: 

 

 

 

 

 

 

 

 

 

 

 

Typical value of piezoelectric ceramic materials

  performance

 

 

 

 

 

 

"Hard" PZT materials

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Properties

 

 

 

 

 

 

PZT-41

 

 

PZT-42

 

 

PZT-43

 

 

PZT-82

 

 

 

 

Dielectric

  Constant

 

 

ɛTr3

 

 

 

 

1050

 

 

1250

 

 

1420

 

 

1100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coupling

  factor 

 

 

KP

 

 

 

 

0.58

 

 

0.58

 

 

0.58

 

 

0.52

 

 

 

 

 

 

K31

 

 

 

 

0.32

 

 

0.33

 

 

0.34

 

 

0.3

 

 

 

 

 

 

K33

 

 

 

 

0.66

 

 

0.67

 

 

0.68

 

 

0.57

 

 

 

 

 

 

Kt

 

 

 

 

0.48

 

 

0.48

 

 

0.48

 

 

0.4

 

 

 

 

Piezoelectric

  coefficient

 

 

d31

 

 

10-12m/v

 

 

-106

 

 

-124

 

 

-138

 

 

-100

 

 

 

 

 

 

d33

 

 

10-12m/v

 

 

260

 

 

280

 

 

300

 

 

240

 

 

 

 

 

 

g31

 

 

10-3vm/n

 

 

-11.4

 

 

-11.2

 

 

-11

 

 

-10.3

 

 

 

 

 

 

g33

 

 

10-3vm/n

 

 

28

 

 

25.3

 

 

24

 

 

25

 

 

 

 

Frequency

  coefficients

 

 

Np

 

 

 

 

2280

 

 

2200

 

 

2160

 

 

2280

 

 

 

 

 

 

N1

 

 

 

 

1671

 

 

1613

 

 

1583

 

 

1671

 

 

 

 

 

 

N3

 

 

 

 

1950

 

 

1900

 

 

1875

 

 

1950

 

 

 

 

 

 

Nt

 

 

 

 

2250

 

 

2200

 

 

2200

 

 

2300

 

 

 

 

Elastic

  compliance coefficient

 

 

Se11

 

 

10-12m2/n

 

 

11.8

 

 

12.7

 

 

13.2

 

 

11.6

 

 

 

 

Machanical

  quality factor

 

 

Qm

 

 

 

 

1000

 

 

800

 

 

600

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dielectric

  loss factor

 

 

Tg δ

 

 

%

 

 

0.3

 

 

0.4

 

 

0.5

 

 

0.3

 

 

 

 

Density

 

 

ρ

 

 

g/cm3

 

 

7.5

 

 

7.5

 

 

7.5

 

 

7.6

 

 

 

 

Curie

  Temperature

 

 

Tc

 

 

°C

 

 

320

 

 

320

 

 

320

 

 

310

 

 

 

 

Young's

  modulus

 

 

YE11

 

 

<109N/m3

 

 

85

 

 

79

 

 

76

 

 

86

 

 

 

 

Poison Ratio

 

 

 

 

 

 

0.3

 

 

0.3

 

 

0.3

 

 

0.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  https://www.yhpiezo.com/hifu-piezoelectric-ceramic-parts/