Change-over Inline Oil Filter Housing and Filter Cartridge

0 votes
asked Jul 16, 2022 in 3D Segmentation by netcec001 (677,960 points)
Change-over Inline Oil Filter (SDFLND)

 

 

---DIN 24550

 

 

----up to 400 L/min

 

 

---up to 63bar

 

 

---material:aluminum

 

 

 

 

 

 

1. Technical

Specifications

 

 

1.1 Filter Housing

 

 

Construction

 

 

The filter housings

are designed in accordance with international regulations. They consist of a

filter head with built-in change-over valve and screw-in filter bowls.

 

 

 

 

 

Standard equipment:

 

 

*  without bypass valve

 

 

*  connection for a clogging indicator

 

 

*  oil drain plug (FLND 160 to 400)

 

 

 

 

 

1.2  Filter

Elements

 

 

Max.

Allowable D.P.:

 

 

BN/HC:20bar;  W/HC: 20bar   

 

 

 

 

 

2.     

Description

 

 

Mounting       

        as inline oil filter

 

 

Temperature range   

- 30 ℃ ~ + 100 ℃

 

 

Pressure setting of clogging indicator △ Pa= 5bar

-0.5bar (others on request)

 

 

Cracking pressure of bypass valve △ Po=7

bar±0.5bar (others on request)

 

 

Seals    NBR

(=Perbunan) /Nitrile Butadiene Rubber

 

 

 

 

 

3.      Notes

 

 

*  Filter

housings must be earthed.

 

 

*  When

using electrical clogging indicators, the electrical power supply to the system

must be switched off before removing the clogging indicator connector.

 

 

*  Filters

with switching valve are designed to have a permissible leakage depending on

the operating medium.

 

 

 

 

 

 

4.      Application

 

 

It can be used for mineral oils, lubrication

oils, non-flam fluids, synthetic and rapidly biodegradable fluids.

 

 

 

 

 

 