Change-over Inline Oil Filter (SDFLND)
---DIN 24550
----up to 400 L/min
---up to 63bar
---material:aluminum
1. Technical
Specifications
1.1 Filter Housing
Construction
The filter housings
are designed in accordance with international regulations. They consist of a
filter head with built-in change-over valve and screw-in filter bowls.
Standard equipment:
* without bypass valve
* connection for a clogging indicator
* oil drain plug (FLND 160 to 400)
1.2 Filter
Elements
Max.
Allowable D.P.:
BN/HC:20bar; W/HC: 20bar
2.
Description
Mounting
as inline oil filter
Temperature range
- 30 ℃ ~ + 100 ℃
Pressure setting of clogging indicator △ Pa= 5bar
-0.5bar (others on request)
Cracking pressure of bypass valve △ Po=7
bar±0.5bar (others on request)
Seals NBR
(=Perbunan) /Nitrile Butadiene Rubber
3. Notes
* Filter
housings must be earthed.
* When
using electrical clogging indicators, the electrical power supply to the system
must be switched off before removing the clogging indicator connector.
* Filters
with switching valve are designed to have a permissible leakage depending on
the operating medium.
4. Application
It can be used for mineral oils, lubrication
oils, non-flam fluids, synthetic and rapidly biodegradable fluids.
5. Photos
https://www.shengdafiltration.com/inline-filter/