Original Title Six Points for Attention for Medical Staff Working in Nucleic Acid Sampling Workstation of Nucleic Acid Sampling Kiosk! Nosocomial infection prevention and control system of nucleic acid sampling point Due to the recent infection due to nucleic acid sampling the infection prevention and control system of nucleic acid sampling points was formulated according to the nucleic acid testing manual and the actual situation of the hospital I Sampling point selection and requirements Shan Limei I3O2I663O95 1 COVID-19 sampling sites should be safe The principle of being scientific and convenient for the people Sampling points should be relatively independent spaces with ventilation conditions corresponding clean areas and contaminated areas equipped with hand hygiene facilities or hand disinfection devices and the sampling process should be "one person one area" The outdoor sampling points shall arrange the sampling space reasonably according to the number of personnel and set the waiting area according to the risk Ensure the one-way flow of personnel as far as possible implement the "1 meter line" spacing requirements and strictly control the density of personnel 2 Indoor air is sterilized by air sterilizer or ultraviolet lamp every day Disinfect for 3 times 1 hour each time Wipe and disinfect the tabletop and countertop with 1000 mg/L Medical Disposable Coverall available chlorine or 75% ethanol for 3 times every day Disinfect at any time if contaminated 3 Environmental sample of sampling point Once every 14 days

 

 The self-sealing bag shall be opened in the biosafety cabinet and the specimen shall be taken out The specimen information shall be checked in detail and the handover registration shall be made IV Hand hygiene occupational exposure and spill treatment 1 Hand hygiene 。 All personnel participating in the field work at the sampling point shall strengthen hand hygiene free shipping disposable coverall and can use alcohol-containing quick-drying hand disinfectant and hydrogen peroxide hand disinfectant; if there are visible pollutants hand sanitizer shall be used to wash hands under flowing water and then disinfect Specimen collectors should strictly implement the principle of "one person one collection and one hand elimination" to prevent cross infection After the job is done wash your hands under running water using hand sanitizer and then disinfect your hands 2 Skin Mucosal and respiratory exposure When the skin is contaminated by pollutants the pollutants should be removed immediately with running water and soap solution If the skin is damaged it should be wiped and disinfected with iodophor or alcohol disinfectant The mucosa should be washed with a large amount of normal saline or iodophor 3 Emergency disposal of overflow 。

A small amount of contaminants can be carefully removed with disposable absorbent materials (such as gauze rags etc) Dipped with chlorine-containing disinfectant solution with available chlorine of 5000mg/L-10000 mg/L (or disinfectant wipe/dry Medical Quickly Delivery Antivirus Coverall towel that can reach a high level of disinfection) After removal disinfect with chlorine-containing disinfectant solution of 1000mg/L and then clean V Disposal of Medical Waste After the sampling the sampling personnel shall write the source of waste the type of medical waste and the date of handover seal it with a double-layer yellow medical waste bag and a gooseneck knot make a good identification and handover with the collection personnel and sign both Pay attention to sealing when the medical waste reaches 3/4 of the loading capacity Disinfect with 1000 mg/L chlorine-containing disinfectant solution after handover and transfer and wipe with clean water after 30 minutes VI Disinfection of Environmental Ground 1 Sampling points shall be ventilated as much as possible The air sterilizer can be used to sterilize people three times a day Ultraviolet rays can be used to disinfect the air in the absence of people The ultraviolet radiation illumination should be ≥ 70 μW/cm2 and the irradiation time should be more than 1 hour Record the irradiation time and the cumulative irradiation time 2 Items on the ground and in the room When there is no obvious contamination on the surface of tables and chairs use disinfectant containing chlorine disinfectant (500-1000 mg/L) to wipe and wipe with clean water to remove the residual disinfectant Disinfect three times a day 3 Ground When the walls or the surfaces of the above objects are obviously contaminated by blood body fluids etc Or splashed by secretions etc disinfectant wipe or disposable absorbent materials (such as absorbent paper gauze etc) Should be used in a timely manner to dip disinfectant solution with an effective chlorine content of 10000 mg/L to remove visible liquid pollutants and then spray or wipe with chlorine-containing disinfectant solution of 1000mg/L Return to Sohu to see more Responsible Editor (function() { function getBrandHtml() { var brands = [] html = ''; for(var i = 0; i < brandslength; i++) { var brand = brands[i]; if(brandslength i+1) { html+= ''+brandname+''; } else { html+= ''+brandname+'、'; } } return html; }; if(documentgetElementById('linkBtn')){ documentgetElementById('linkBtn')onclick = function() { $('#brands')removeClass('brand');$ ( '# tipInfo')text ( 'Real name responded'); $ ('#linkBtn')remove();$ ('real-response content')css('line-height' '20px');$ ('real-response time')css('line-height' '20px'); }; documentgetElementById('brands')innerHTML = getBrandHtml(); }; })();。 zjyuan-group.com

Please log in or register to answer this question.

Welcome to Bioimagingcore Q&A, where you can ask questions and receive answers from other members of the community.
...